V1500 - 115 Gallon Drum Storage Cabinet, Self-Latch Standard 2 Door

SKU: V1500

Features & Specifications

Description

Safe, convenient and centralized storage for Flammables. Vertical Drum Cabinets have ball bearing rollers for easy placing and removal of 55 gallon drums. From one to twelve 5-gallon safety cans can also be stored depending on the model. Horizontal Cabinets store one 55 gallon drum and one 5 gallon safety can. Drum cradles available. Horizontal cabinets have tracks to guide Drum Cradle into position. Choose from 3 door styles.

 

Specifications

Item No.V1500
Capacity115 Gallon (1-55 Gal. Drum & 12-5 Gal Safety Cans)
Dimension (H x W x D) (in)65"H x 56"W x 31"D
No. of Doors2
Door StyleSelf-Latch Standard Door
No of Shelves3
Shipping Weight (lbs)600 Lbs.
ApprovalComplies with current OSHA regulations, FM-Factory Mutual Approved, NFPA - Designed in accordance with specifications set forth by the National Fire Protection Association
Warranty15 Year Limited Structural Warranty

Standard Features

All Securall cabinets are built to the highest quality specifications. Whether you are storing dangerous flammable chemicals or you need a cabinet for heavy industrial tools, we have the perfect cabinet for your needs. If you have a special situation that requires a customized design, we will welcome the opportunity to work with you to provide a safe storage solution. All cabinets comply with current OSHA regulations and are designed in accordance with the standards of NFPA Code 30. Popular models are FM Approved.

  • 18 GAUGE DOUBLE WALL CONSTRUCTION & SEAMED JOINTS          
    Securall Safety Cabinets have Structurally Reinforced 18-Gauge Double Wall All Welded Construction throughout.

  • DOUBLE WALL CONSTRUCTION WITH 1 ½” AIR SPACE         
    Securall cabinets have Double Wall Construction with 1 ½" Air Space throughout the cabinet design.

  • 2" DEEP LEAK PROOF SILL         
    Securall cabinets are built with an OSHA compliant leak proof sill 2" Deep to prevent leakage in the event of accidental spills.

  • NON-SPARKING , 3-POINT, SELF-LATCHING DOORS         
    Each Securall cabinet is outfitted with FM required Non-Sparking, 3-Point, Self-Latching door(s) for safe and complete closure every time.

  • SELF-CLOSING MECHANISM (IF INSTALLED) SEGREGATED FROM HAZARD AREA         
    Securall Self Closing Cabinet - Self closing mechanism segregated from interior of cabinet and contents stored.

  • FUSIBLE LINK ASSEMBLY ON SELF-CLOSING MODELS         
    Self-Closing cabinets come with Fusible Link Assembly. Link melts at 165 F for automatic closure in case of fire. Self closing mechanism segregated from hazard area.

  • STATIC GROUNDING CONNECTION         
    All Securall cabinets come ready with an FM defined static ground connection, comprised of a NFPA compliant 5/16 - 18 x ½” Zinc Plated Grounding Bolt.

  • LARGE WARNING LABEL         
    Securall cabinets have a Large Warning Label to identify the type of material stored within the unit. Also available in French and Spanish.

  • ADJUSTABLE LEVELING LEGS         
    Securall cabinets are equipped with four adjustable Zinc Plated Leveling Legs for placement on uneven surface areas.

  • FLUSH MOUNTED LOCKING HANDLE         
    All Securall safety cabinets come standard with a Flush Mounted Locking Handle for smooth finger-tip operation.

  • FULL LENGTH, HEAVY-DUTY PIANO HINGES         
    Securall double-wall doors are secured to unit on full length, Heavy-Duty Piano Hinges for maximum security and limited vapor release.

Accessories

Loading...

Attributes

Capacity 115 Gallon
Cabinet Venting Yes
Number of Shelves 2
WeatherProof Package No
Warranty 15 Year Structural Limited
Use Cases Flammable, Flammable Drum Storage
Storing 55 Gal Drums, Safety Cans
Door Type Self-Latch Standard 2 Door
Dimension (H x W x D) 65"H x 56"W x 31"D
Approvals OSHA, FM, NFPA
Nmfc Class 125

Reviews

Loading product reviews...

Paint Color

The interior and exterior finish consists of an aliphatic polyurethane finish. This polyurethane coating has chemical properties to withstand salt spray, chemical rub, fading due to UV exposure, and other tests performed to epoxy paints. Urethane is more durable under conditions when moving items in and out of the cabinet as it resists chipping and peeling. Unless some other color is specified, cabinets will ship in designated standard color. For custom colors, customer must provide a paint chip.

Flammable & Combustible Classes

NFPA FLAMMABLE & COMBUSTIBLE CLASSES

FLAMMABLES FLASH POINT BOILING POINT
Class IA <73°F (22.8°C) <100°F (37.8°C)
Class IB <73°F (22.8°C) >=100° F
Class IC <73°F (22.8°C) and <100°F (37°C) >100° F

 

COMBUSTIBLES FLASH POINT BOILING POINT
Class II 100° F (37.8° C) ≤ FP < 140° F (60° C) -
Class IIIA 140° F (60° C) ≤ FP < 200° F (93° C) -
Class IIIB 200° F (93° C) ≤ FP -

9.5.1 The volume of Class I, Class II, and Class IIIA liquids stored in an individual storage cabinet shall not exceed 120 gal (460 L). 

9.5.2 The total aggregate volume of Class I, Class II, and Class IIIA liquids in a group of storage cabinets shall not exceed the maximum allowable quantity of flammable and combustible liquids per control area based on the occupancy where the cabinets are located.

* NFPA 30 Flammable and Combustible Liquids Code, 2011 Edition. Section 9.5.1, 9.5.2

FM Approved Fire Rating

Fire Rating According to FM

Securall Fire-Rated Storage Buildings (8'4"H X 42'W X 9'D Max Dimensions) carry the Factory Mutual System Approval label and have an FM Approved Fire Rated Wall & Roof Design. Wall and Roof are Tested at Intertek Testing Laboratories. Securall Fire-Rated Storage Buildings constructed based upon UL Fire Resistance Ratings classification criteria. Standard models are available in 2-hour and 4-hour fire ratings. Wall ratings are either 2 or 4 hour fire rated . Roof ratings are either 1.5 or 3 hour fire rated (Check with your local authority having jurisdiction for correct wall/roof rating needed). In addition, all Fire-Rated Buildings come with hydraulic operated self-closing, fire-rated doors and fire damper protected vents.

Industry's 1st & Only Intertek Tested and FM Approved 2 Hour Fire Rated wall construction built with 1.5 hour fire rated roof construction, 1.5 hour fire rated door construction, and multiple layers of ¾” gypsum ultracode wallboard. Air inlet vents with UL Listed and labeled fire damper with louvers. Dampers have a galvanized steel frame, curtain-type galvanized steel blades and a UL Listed 165° F fusible link.

Industry's 1st & Only Intertek Tested and FM Approved 4 Hour Fire Rated wall construction built with 3 hour fire rated roof construction, 3 hour fire rated door construction, and multiple layers of ¾” gypsum ultracode wallboard. Air inlet vents with UL Listed and labeled fire damper with louvers. Dampers have a galvanized steel frame, curtain-type galvanized steel blades and a UL Listed 165° F fusible link.

Please check with your local authority having jurisdiction for setback requirements and correct wall/roof rating needed.

Hurricane Resistant Wall Design

 

Securall Buildings have been tested to determine the amount of force they can withstand and were shown to withstand F-4 tornado force winds of 250 mph. The chart below demonstrates the wind speed that a particular length of wall will resist.

Upgrade package is available for Tornado Resistant Walls.

I B C wind speed

 

Securall Hazamat Storage Buildings are all-welded using 12 gauge (B1600X-B8000X Models) and 16 gauge (B200X-B1200X Models) galvannealed steel outer walls and 20 gauge cold rolled steel inner walls provide maximum durability, weather resistance, and rigidity.

Fire rated wall design

Engineered Solutions

[Engineered solutions content and link to RFQ page]

Installation Instructions

Loading product details...