Features & Specifications
Description
EPA regulations help ensure that facilities take steps to prevent oil spills, chemical accidents, and other emergencies, as well as implement planning and response requirements. EPA's emergency management activities and regulations help protect the environment and human health from releases or discharges of oil, chemicals, or other hazardous substances.
Choose from three popular sizes. Our larger full size cabinets are stationary and our smaller mobile model allows you to respond to cleanups by simply wheeling your supplies to the spill area. The wall-mounted cabinet keeps all your spill control supplies available without taking up floor space.
Specifications
Item No. | SCC242 |
Capacity | 21 Cubic Feet |
Dimension (H x W x D) (in) | 42"H x 36"W x 24"D |
No. of Doors | 1 Manual Door |
No of Shelves | 2 |
Shipping Weight (lbs) | 200 Lbs. |
Warranty | 15 Year Limited Structural Warraty |
Standard Features
All Securall cabinets are built to the highest quality specifications. Whether you are storing dangerous flammable chemicals or you need a cabinet for heavy industrial tools, we have the perfect cabinet for your needs. If you have a special situation that requires a customized design, we will welcome the opportunity to work with you to provide a safe storage solution. All cabinets comply with current OSHA regulations and are designed in accordance with the standards of NFPA Code 30. Popular models are FM Approved.
18 GAUGE DOUBLE WALL CONSTRUCTION & SEAMED JOINTS
Securall Safety Cabinets have Structurally Reinforced 18-Gauge Double Wall All Welded Construction throughout.DOUBLE WALL CONSTRUCTION WITH 1 ½” AIR SPACE
Securall cabinets have Double Wall Construction with 1 ½" Air Space throughout the cabinet design.2" DEEP LEAK PROOF SILL
Securall cabinets are built with an OSHA compliant leak proof sill 2" Deep to prevent leakage in the event of accidental spills.NON-SPARKING , 3-POINT, SELF-LATCHING DOORS
Each Securall cabinet is outfitted with FM required Non-Sparking, 3-Point, Self-Latching door(s) for safe and complete closure every time.SELF-CLOSING MECHANISM (IF INSTALLED) SEGREGATED FROM HAZARD AREA
Securall Self Closing Cabinet - Self closing mechanism segregated from interior of cabinet and contents stored.FUSIBLE LINK ASSEMBLY ON SELF-CLOSING MODELS
Self-Closing cabinets come with Fusible Link Assembly. Link melts at 165 F for automatic closure in case of fire. Self closing mechanism segregated from hazard area.STATIC GROUNDING CONNECTION
All Securall cabinets come ready with an FM defined static ground connection, comprised of a NFPA compliant 5/16 - 18 x ½” Zinc Plated Grounding Bolt.LARGE WARNING LABEL
Securall cabinets have a Large Warning Label to identify the type of material stored within the unit. Also available in French and Spanish.ADJUSTABLE LEVELING LEGS
Securall cabinets are equipped with four adjustable Zinc Plated Leveling Legs for placement on uneven surface areas.FLUSH MOUNTED LOCKING HANDLE
All Securall safety cabinets come standard with a Flush Mounted Locking Handle for smooth finger-tip operation.FULL LENGTH, HEAVY-DUTY PIANO HINGES
Securall double-wall doors are secured to unit on full length, Heavy-Duty Piano Hinges for maximum security and limited vapor release.
Attributes
WeatherProof Package | Yes |
---|---|
Warranty | 15 Year Structural Limited |
Use Cases | Spill Containment |
Capacity | 15 Cubic Feet |
Number of Shelves | 2 |
Cabinet Venting | No |
Door Type | Self-Latch Standard Door |
Dimension (H x W x D) | 42"H x 36"W x 24"D |
Approvals | OSHA, NFPA |
Nmfc Class | 125 |
Accessories
Reviews
Paint Color
The interior and exterior finish consists of an aliphatic polyurethane finish. This polyurethane coating has chemical properties to withstand salt spray, chemical rub, fading due to UV exposure, and other tests performed to epoxy paints. Urethane is more durable under conditions when moving items in and out of the cabinet as it resists chipping and peeling. Unless some other color is specified, cabinets will ship in designated standard color. For custom colors, customer must provide a paint chip.
Flammable & Combustible Classes
FM Approved Fire Rating
Fire Rating According to FM
Securall Fire-Rated Storage Buildings (8'4"H X 42'W X 9'D Max Dimensions) carry the Factory Mutual System Approval label and have an FM Approved Fire Rated Wall & Roof Design. Wall and Roof are Tested at Intertek Testing Laboratories. Securall Fire-Rated Storage Buildings constructed based upon UL Fire Resistance Ratings classification criteria. Standard models are available in 2-hour and 4-hour fire ratings. Wall ratings are either 2 or 4 hour fire rated . Roof ratings are either 1.5 or 3 hour fire rated (Check with your local authority having jurisdiction for correct wall/roof rating needed). In addition, all Fire-Rated Buildings come with hydraulic operated self-closing, fire-rated doors and fire damper protected vents.
Industry's 1st & Only Intertek Tested and FM Approved 2 Hour Fire Rated wall construction built with 1.5 hour fire rated roof construction, 1.5 hour fire rated door construction, and multiple layers of ¾” gypsum ultracode wallboard. Air inlet vents with UL Listed and labeled fire damper with louvers. Dampers have a galvanized steel frame, curtain-type galvanized steel blades and a UL Listed 165° F fusible link.
Industry's 1st & Only Intertek Tested and FM Approved 4 Hour Fire Rated wall construction built with 3 hour fire rated roof construction, 3 hour fire rated door construction, and multiple layers of ¾” gypsum ultracode wallboard. Air inlet vents with UL Listed and labeled fire damper with louvers. Dampers have a galvanized steel frame, curtain-type galvanized steel blades and a UL Listed 165° F fusible link.
Please check with your local authority having jurisdiction for setback requirements and correct wall/roof rating needed.
Hurricane Resistant Wall Design
Securall Buildings have been tested to determine the amount of force they can withstand and were shown to withstand F-4 tornado force winds of 250 mph. The chart below demonstrates the wind speed that a particular length of wall will resist.
Upgrade package is available for Tornado Resistant Walls.
Securall Hazamat Storage Buildings are all-welded using 12 gauge (B/AG1600X-B/AG8000X Models) and 16 gauge (B/AG200X-B/AG1200X Models) galvannealed steel outer walls and 20 gauge cold rolled steel inner walls provide maximum durability, weather resistance, and rigidity.
Engineered Solutions
[Engineered solutions content and link to RFQ page]