SCC242 - 21 Cubic Ft Counter High Mobile Cabinet

SKU: SCC242

Features & Specifications

Description

EPA regulations help ensure that facilities take steps to prevent oil spills, chemical accidents, and other emergencies, as well as implement planning and response requirements. EPA's emergency management activities and regulations help protect the environment and human health from releases or discharges of oil, chemicals, or other hazardous substances.

Choose from three popular sizes. Our larger full size cabinets are stationary and our smaller mobile model allows you to respond to cleanups by simply wheeling your supplies to the spill area. The wall-mounted cabinet keeps all your spill control supplies available without taking up floor space.

 

Specifications

Item No.SCC242
Capacity21 Cubic Feet
Dimension (H x W x D) (in)42"H x 36"W x 24"D
No. of Doors1 Manual Door
No of Shelves2
Shipping Weight (lbs)200 Lbs.
Warranty15 Year Limited Structural Warraty

Standard Features

All Securall cabinets are built to the highest quality specifications. Whether you are storing dangerous flammable chemicals or you need a cabinet for heavy industrial tools, we have the perfect cabinet for your needs. If you have a special situation that requires a customized design, we will welcome the opportunity to work with you to provide a safe storage solution. All cabinets comply with current OSHA regulations and are designed in accordance with the standards of NFPA Code 30. Popular models are FM Approved.

  • 18 GAUGE DOUBLE WALL CONSTRUCTION & SEAMED JOINTS           
    Securall Safety Cabinets have Structurally Reinforced 18-Gauge Double Wall All Welded Construction throughout.

  • DOUBLE WALL CONSTRUCTION WITH 1 ½” AIR SPACE          
    Securall cabinets have Double Wall Construction with 1 ½" Air Space throughout the cabinet design.

  • 2" DEEP LEAK PROOF SILL          
    Securall cabinets are built with an OSHA compliant leak proof sill 2" Deep to prevent leakage in the event of accidental spills.

  • NON-SPARKING , 3-POINT, SELF-LATCHING DOORS          
    Each Securall cabinet is outfitted with FM required Non-Sparking, 3-Point, Self-Latching door(s) for safe and complete closure every time.

  • SELF-CLOSING MECHANISM (IF INSTALLED) SEGREGATED FROM HAZARD AREA          
    Securall Self Closing Cabinet - Self closing mechanism segregated from interior of cabinet and contents stored.

  • FUSIBLE LINK ASSEMBLY ON SELF-CLOSING MODELS          
    Self-Closing cabinets come with Fusible Link Assembly. Link melts at 165 F for automatic closure in case of fire. Self closing mechanism segregated from hazard area.

  • STATIC GROUNDING CONNECTION          
    All Securall cabinets come ready with an FM defined static ground connection, comprised of a NFPA compliant 5/16 - 18 x ½” Zinc Plated Grounding Bolt.

  • LARGE WARNING LABEL          
    Securall cabinets have a Large Warning Label to identify the type of material stored within the unit. Also available in French and Spanish.

  • ADJUSTABLE LEVELING LEGS          
    Securall cabinets are equipped with four adjustable Zinc Plated Leveling Legs for placement on uneven surface areas.

  • FLUSH MOUNTED LOCKING HANDLE          
    All Securall safety cabinets come standard with a Flush Mounted Locking Handle for smooth finger-tip operation.

  • FULL LENGTH, HEAVY-DUTY PIANO HINGES          
    Securall double-wall doors are secured to unit on full length, Heavy-Duty Piano Hinges for maximum security and limited vapor release.

Attributes

WeatherProof Package Yes
Warranty 15 Year Structural Limited
Use Cases Spill Containment
Capacity 15 Cubic Feet
Number of Shelves 2
Cabinet Venting No
Door Type Self-Latch Standard Door
Dimension (H x W x D) 42"H x 36"W x 24"D
Approvals OSHA, NFPA
Nmfc Class 125

Accessories

Loading...

Reviews

Loading product reviews...

Paint Color

The interior and exterior finish consists of an aliphatic polyurethane finish. This polyurethane coating has chemical properties to withstand salt spray, chemical rub, fading due to UV exposure, and other tests performed to epoxy paints. Urethane is more durable under conditions when moving items in and out of the cabinet as it resists chipping and peeling. Unless some other color is specified, cabinets will ship in designated standard color. For custom colors, customer must provide a paint chip.

Flammable & Combustible Classes

NFPA FLAMMABLE & COMBUSTIBLE CLASSES

FLAMMABLES FLASH POINT BOILING POINT
Class IA <73°F (22.8°C) <100°F (37.8°C)
Class IB <73°F (22.8°C) >=100° F
Class IC <73°F (22.8°C) and <100°F (37°C) >100° F

 

COMBUSTIBLES FLASH POINT BOILING POINT
Class II 100° F (37.8° C) ≤ FP < 140° F (60° C) -
Class IIIA 140° F (60° C) ≤ FP < 200° F (93° C) -
Class IIIB 200° F (93° C) ≤ FP -

9.5.1 The volume of Class I, Class II, and Class IIIA liquids stored in an individual storage cabinet shall not exceed 120 gal (460 L). 

9.5.2 The total aggregate volume of Class I, Class II, and Class IIIA liquids in a group of storage cabinets shall not exceed the maximum allowable quantity of flammable and combustible liquids per control area based on the occupancy where the cabinets are located.

* NFPA 30 Flammable and Combustible Liquids Code, 2011 Edition. Section 9.5.1, 9.5.2

FM Approved Fire Rating

Fire Rating According to FM

Securall Fire-Rated Storage Buildings (8'4"H X 42'W X 9'D Max Dimensions) carry the Factory Mutual System Approval label and have an FM Approved Fire Rated Wall & Roof Design. Wall and Roof are Tested at Intertek Testing Laboratories. Securall Fire-Rated Storage Buildings constructed based upon UL Fire Resistance Ratings classification criteria. Standard models are available in 2-hour and 4-hour fire ratings. Wall ratings are either 2 or 4 hour fire rated . Roof ratings are either 1.5 or 3 hour fire rated (Check with your local authority having jurisdiction for correct wall/roof rating needed). In addition, all Fire-Rated Buildings come with hydraulic operated self-closing, fire-rated doors and fire damper protected vents.

Industry's 1st & Only Intertek Tested and FM Approved 2 Hour Fire Rated wall construction built with 1.5 hour fire rated roof construction, 1.5 hour fire rated door construction, and multiple layers of ¾” gypsum ultracode wallboard. Air inlet vents with UL Listed and labeled fire damper with louvers. Dampers have a galvanized steel frame, curtain-type galvanized steel blades and a UL Listed 165° F fusible link.

Industry's 1st & Only Intertek Tested and FM Approved 4 Hour Fire Rated wall construction built with 3 hour fire rated roof construction, 3 hour fire rated door construction, and multiple layers of ¾” gypsum ultracode wallboard. Air inlet vents with UL Listed and labeled fire damper with louvers. Dampers have a galvanized steel frame, curtain-type galvanized steel blades and a UL Listed 165° F fusible link.

Please check with your local authority having jurisdiction for setback requirements and correct wall/roof rating needed.

Hurricane Resistant Wall Design

 

Securall Buildings have been tested to determine the amount of force they can withstand and were shown to withstand F-4 tornado force winds of 250 mph. The chart below demonstrates the wind speed that a particular length of wall will resist.

Upgrade package is available for Tornado Resistant Walls.

I B C wind speed

 

Securall Hazamat Storage Buildings are all-welded using 12 gauge (B/AG1600X-B/AG8000X Models) and 16 gauge (B/AG200X-B/AG1200X Models) galvannealed steel outer walls and 20 gauge cold rolled steel inner walls provide maximum durability, weather resistance, and rigidity.

Fire rated wall design

Engineered Solutions

[Engineered solutions content and link to RFQ page]

Installation Instructions

Loading product details...