1-888-326-7890
  FLAMMABLE STORAGE
DRUM STORAGE
PAINT & INK STORAGE
LABORATORY STORAGE
ACID & CORROSIVE
HAZARDOUS WASTE STORAGE
LP CYLINDER STORAGE
MEDICAL GAS STORAGE
WALL MOUNTED CABINETS
PESTICIDE STORAGE
SPILL CONTAINMENT CABINET
INDUSTRIAL STORAGE
OFFICE & TOOLING STORAGE
WEATHER PROOF CABINETS
DUAL ACCESS CABINETS
MOBILE WORK BENCHES

MEDICAL (Oxygen) GAS CYLINDER CABINETS

SECURALL® offers Medical Gas Cylinder Storage Cabinets for safe and compliant storage of portable oxygen cylinders. These Oxygen Gas Cylinder Storage Cabinets are ideal for hospitals and nursing homes for convenient access. SECURALL® storage cabinets store oxygen gas cylinders safely and in compliance with OSHA and NFPA standards.

 

 

  STORAGE BUILDINGS
  HAZMAT STORAGE
  CHEMICAL STORAGE
  EXPLOSIVE STORAGE
  CUSTOM BUILDING - Form

 STAINLESS STEEL
  FLAMMABLE CABINET
  GENERAL STORAGE

  SAFETY CABINET
  VIEW ALL CABINETS
  STANDARD FEATURES
  CODE & COMPLIANCE
  CUSTOM CABINET [Form]
  CABINET ACCESSORIES


  GUN CABINETS
  GUN SAFES SECURALL® also manufactures a quality line of firearm & high security safes, which carry a superior 1700°F/1 hour fire rating. Read More >>  
 
 
 
 

  SECURALL® Strives to know and understand the most current codes and regulations..Why it is Your Responsibility to Know your Cabinet is Compliant?? Read More >>
OSHA Training & Education
 
 

 PRESS RELEASE

 SHIPPING & CANCELLATION

GS-28F-0010B; SIN 71-312 & 71-310

 

 

 


MEDICAL [OXYGEN] GAS CYLINDER CABINETS

Store your portable Medical Gas Cylinder safely and in compliance with OSHA requirements. SECURALL® Oxygen Gas Cylinder Storage Cabinets are designed to meet storage requirements for portable medical oxygen systems as set forth in:

• NFPA Code 99 - Health Care Facilities - 1999 Edition
• NFPA Code 101 - Life Safety - 2000 Edition
• NFPA Code 30 - Flammable and Combustible Liquids - 2003
• Edition OSHA Regulations

These lockable gas storage cabinets limit access to authorized personnel, protecting cylinders from theft, damage and/or tampering. The heavy-gauge, double-walled construction shields your cylinders from heat, sparks and flame, while separating them from flammable and combustible materials.

Storing Full, Partial & Empty Cylinders - Are you in compliance??

Improper storage of medical gas cylinders poses a number of hazards to patients and staff. The National Fire Protection Association’s regulation NFPA 99-1999 section 4-3.5.2.2(b) mandates requirements for storing nonflammable gas cylinders. The Joint Commission requires compliance with the NFPA requirements under Environment of Care standards EC.02.06.01, EP 1 and EC.02.03.01, EP 1.

Segregate cylinders: The Joint Commission requires organizations to segregate full, partial and empty cylinders by physically separating and clearly labeling the cylinders. Once a cylinder valve is opened, it is considered empty, even if gas remains in the cylinder. For storage purposes, any opened cylinders must be physically separated from full (unopened) cylinders.

Securall offers separate product lines to store Full, Partial, and Empty Cylinders. Optional adjustable divider is available to segregate cylinders for 9-12 and 21-24 cylinder storage cabinets.

   
 1-2 CYLINDER STORAGE CABINETS
MG102 - Self-Latch Standard Door; Dimension 44"H x 14"W x 9"D; Holds 1-2 D, E Cylinders; Approx. Ship. Wt. 97 Lbs.
Approval - OSHA, NFPA
[More..]

quick Quote
MG102FL - Self-Latch Standard Door, Fire Lined ; Dimension 44"H x 14"W x 9"D; Holds 1-2 D, E Cylinders; Approx. Ship. Wt. 112 Lbs.
Approval - OSHA, NFPA
[More..]

quick Quote
     


 2-4 CYLINDER STORAGE CABINETS
MG104 - Self-Latch Standard Door; Dimension 44"H x 14"W x 13-5/8"D; Holds 2-4 D, E Cylinders; Approx. Ship. Wt. 115 Lbs.
Approval - OSHA, NFPA
[More..]

quick Quote
MG104FL - Self-Latch Standard Door, Fire Lined; Dimension 44"H x 14"W x 13-5/8"D; Holds 2-4 D, E Cylinders; Approx. Ship. Wt. 135 Lbs.
Approval - OSHA, NFPA
[More..]

quick Quote
MG304 - Self-Latch Self-Close Safe-T-Door; Dimension 46"H x 14 x 13-5/8"D; Holds 1-2 D, E Cylinders; Approx. Ship. Wt. 125 Lbs.
Approval - OSHA, NFPA
[More..]

quick Quote
MG304FL - Self-Latch Self-Close Safe-T-Door, Fire Lined; Dimension 46"H x 14"W x 13-5/8"D; Holds 2-4 D, E Cylinders; Approx. Ship. Wt. 145 Lbs.
Approval - OSHA, NFPA
[More..]

quick Quote
     

 9-12 CYLINDER STORAGE CABINETS
MG109 - Self-Latch Standard Door; Dimension 44"H x 23"W x 18"D; Holds 9-12 D, E Cylinders; Approx. Ship. Wt. 170 Lbs.
Approval - OSHA, NFPA
[More..]


quick Quote
MG109FL - Self-Latch Standard Door, Fire Lined; Dimension 44"H x 23"W x 18"D; Holds 9-12 D, E Cylinders; Approx. Ship. Wt. 199 Lbs.
Approval - OSHA, NFPA
[More..]


quick Quote
MG309 - Self-Latch Self-Close Safe-T-Door; Dimension 46"H x 23"W x 18 Inch; Holds 9-12 D, E Cylinders; Approx. Ship. Wt. 180 Lbs.
Approval - OSHA, NFPA
[More..]

quick Quote
MG309FL - Self-Latch Self-Close Safe-T-Door, Fire Lined; Dimension 46"H x 23"W x 18"D; Holds 9-12 D, E Cylinders; Approx. Ship. Wt. 209 Lbs.
Approval - OSHA, NFPA
[More..]

quick Quote
   

 21-24 CYLINDER STORAGE CABINETS
MG121 - Self-Latch Standard Door; Dimension 44"H x 43"W x 18"D; Holds 21-24 D, E Cylinders; Approx. Ship. Wt. 265 Lbs.
Approval - OSHA, NFPA
[More..]


quick Quote
MG121-FL - Self-Latch Standard Door, Fire Lined; Dimension 44"H x 43"W x 18"D; Holds 21-24 D, E Cylinders; Approx. Ship. Wt. 308 Lbs.
Approval - OSHA, NFPA
[More..]


quick Quote
MG321 - Self-Latch Self-Close Safe-T-Door; Dimension 46"H x 43"W x 18"D; Holds 21-24 D, E Cylinders; Approx. Ship. Wt. 280 Lbs.
Approval - OSHA, NFPA
[More..]


quick Quote
MG321FL - Self-Latch Self-Close Safe-T-Door, Fire Lined; Dimension 46"H x 43"W x 18"D; Holds 21-24 D, E Cylinders; Approx. Ship. Wt. 323 Lbs.
Approval - OSHA, NFPA
[More..]

quick Quote
 


 6-9 H CYLINDER STORAGE CABINETS
MG106H - Self-Latch Standard Door; Dimension 65"H x 34"W x 34"D; Holds 6-9 H Cylinders; Approx. Ship. Wt. 372 Lbs.
Approval - OSHA, NFPA
[More..]


quick Quote
MG106HFL - Self-Latch Standard Door, Fire Lined; Dimension 65"H x 34"W x 34"D; Holds 6-9 H Cylinders; Approx. Ship. Wt. 436 Lbs.
Approval - OSHA, NFPA
[More..]


quick Quote
MG306H - Self-Latch Self-Close Safe-T-Door; Dimension 67"H x 34"W x 34"D; Holds 6-9 H Cylinders; Approx. Ship. Wt. 394 Lbs.
Approval - OSHA, NFPA
[More..]

quick Quote
MG306HFL - Self-Latch Self-Close Safe-T-Door, Fire Lined; Dimension 67"H x 34"W x 34"D; Holds 6-9 H Cylinders; Approx. Ship. Wt. 458 Lbs.
Approval - OSHA, NFPA
[More..]

quick Quote
     
 9-12 H CYLINDER STORAGE CABINETS
MG109H - Self-Latch Standard Door; Dimension 65"H x 43"W x 34"D; Holds 9-12 H Cylinders; Approx. Ship. Wt. 443 Lbs.
Approval - OSHA, NFPA
[More..]

quick Quote
MG109HFL - Self-Latch Standard Door, Fire Lined; Dimension 65"H x 43"W x 34"D; Holds 9-12 H Cylinders; Approx. Ship. Wt. 520 Lbs.
Approval - OSHA, NFPA
[More..]


quick Quote
MG309H - Self-Latch Self-Close Safe-T-Door; Dimension 67"H x 43"W x 34"D; Holds 9-12 H Cylinders; Approx. Ship. Wt. 550 Lbs.
Approval - OSHA, NFPA
[More..]


quick Quote
MG309HFL - Self-Latch Self-Close Safe-T-Door, Fire Lined; Dimension 67"H x 43"W x 34"D; Holds 9-12 H Cylinders; Approx. Ship. Wt. 550 Lbs.
Approval - OSHA, NFPA
[More..]

quick Quote
 

  CONSTRUCTION FEATURES
 

* Available with manual or self-closing doors.
* Lockable flush-mounted paddle handle.
* All-welded galvannealed steel construction.
* Conspicuous labeling in English and Spanish.
* Full length piano hnges.
* Shipped fully assembled.
* Adjustable leveling legs.
* Optional caster assembly available.
* Finished in 2 coats of OSHA Safety Green urethane.
* Non-sparking aluminum deviders.
 

   PRODUCTS COMPLIANCE & CODES

NFPA 30 Flammable and Combustible Liquids Code - 2003 Edition

6.3.3 Storage cabinets that meet at least one of the following sets of requirements shall be acceptable for storage of liquids:

  1. Storage cabinets that are designed and constructed to limit the internal temperature at the center of the cabinet and 25 mm (1 in.) from the top of the cabinet to not more than 163° C (325° F), when subjected to a 10-minute fire test that simulates the fire exposure of the standard time temperature curve specified in in NFPA 251, Standard Methods of Tests of Fire Endurance of Building Construction and Materials, shall be acceptable. All joints and seams shall remain tight and the door shall remain securely closed during test.

  2. Metal Storage cabinets that are constructed in the following manner shall be acceptable :

    1. The bottom, top ,door, and sides of the cabinets shall be at least No. 18 gauge sheet steel and shall be double-walled, with 38 mm (1-1/2 in.) air space.

    2. Joints shall be riveted, welded, or made tight by some equally effective means.

    3. The door shall be provided with a three-point latch arrangements, and the doorsill shall be raised at least 50 mm (2 in.) above the bottom of the cabinet to retain spilled liquid within the cabinet.

NFPA 99 Health Care Facility - 1999 Edition

4-3.1.1.2 Storage Requirements (Location, Construction, Arrangement).

(a) Nonflammable gases (Any Quantity; In-Storage, connected, or Both)

1. Storage locations for oxygen and nitrous oxide shall be kept free of flammable materials.

8-3.1.11.2 Storage for nonflammable gases less than 3000 square ft (85 square meter).

  1. Storage locations shall be outdoors in an enclosure or within an enclosed interior space of noncombustible or limited combustible construction, with doors (or gates outdoors) that can be secured against unauthorized entry.

  2. Oxidizing gases, such as oxygen and nitrous oxide, shall not be stored with any flammable gas, liquid, or vapor.

  3. Oxidizing gases such as oxygen and nitrous oxide, shall be separated from combustibles or incompatible materials by either:

    1. A minimum distance of 20 ft (6.1 m), or

    2. A minimum distance of 5 ft (1.5 m) if the entire storage location is protected by an automatic sprinkler system designed in accordance with NFPA 13, Standard for the Installation of Sprinker Systems, or

    3. An enclosed cabinet of noncombustible construction having a minimum fire protection rating of one-half hour cylinder storage. An approved flammable liquid storage cabinet shall be permitted to be used cylinder storage.

NFPA 101 Life Safety Code - 2000 Edition

18.3.2.4 Medical Gas. Medical gas and storage and administration areas shall be protected in a accordance with NFPA 99, Standard for Health Care Facilities.

 
 