ACID & CORROSIVE STORAGE CABINET
The leak tight sump and shelves of the cabinet are equipped with removable corrosive-resistant polyethylene trays to contain accidental spills. Acid Cabinets are finished in corrosive-resistant blue urethane paint. Large warning label reads: "CAUTION CORROSIVES". Or choose your own special message or wording.
Available in 24, 30, 45 and 60 gallon capacities.
BENCHTOP ACID CABINETS (C124 & C224 - 24 Gallon Only)
Keep all acids safe and at hand with SECURALL® Benchtop Flammable/Corrosive Storage Cabinets for both flammable and nonflammable corrosives. Comply with NFPA and current OSHA requirements. Cabinet has a ¾" leak-proof tray top, which can completely contain a 5 pint spill. Cabinets finished in blue corrosive-resistant urethane. Adjustable painted galvannealed steel shelves and bottom lined with removable polyethylene trays; tray-top cabinet lined with removable polyethylene sheet. |
|
|
|
 |
|
| * Double wall construction with 1 ½” air space. |
| * Static grounding bolt Current OSHA compliant. |
| * Reinforced 18-gauge all-welded construction. |
| * Adjustable Painted Galvannealed steel shelving. |
| * Two 2” vents with flash arrestors. |
| * Poly Liner in sump; tray top (24-gal models only). |
| * 3-point self-latching (Non Sparking) doors. |
| * Poly tray on each shelf. |
* Continuous piano hinge. |
| * Leak proof sill 2” deep. |
* Large Warning label. |
| * Flush mounted locking handle. |
| * Finished in 2-part urethane paint. |
| * Adjustable zinc plated leveling legs. |
|
CONTAINMENT CLASSIFICATIONS |
PAINT COLOR |
DOOR STYLE |
|
|
|
| |
NFPA FLAMMABLE & COMBUSTIBLE CLASSES |
| FLAMMABLES |
Flash Point |
Boiling Point |
| Class IA |
<73°F (22.8°C) |
<100°F (37.8°C) |
| Class IB |
<73°F (22.8°C) |
<100°F (37.8°C) |
| Class IC |
<73°F (22.8°C) and <100°F (37°C) |
- |
|
| |
COMBUSTABLES |
Flash Point |
Boiling Point |
| Class IIA |
<100°F (37.8°C) and <140°F (60°C) |
- |
| Class IIIB |
<140°F (60°C) and <200°F (93°C) |
- |
| Class IIIC |
<200°F (93°C) |
- |
|
| A maximum of 120 - gallons of Class I, Class II, and Class IIIA liquids may be stored in a single storage cabinet *. The number of cabinets in a single fire area may not exceed 3. Proper storage of additional cabinets within a single fire area is limited to groups no larger than 3, so long as a minimum of 100ft separation exists between all groups. The maximum number of cabinets in any one group may be increased to 6 if the cabinets are stored in an Industrial Occupancy facility that is equipped with an automatic sprinkler system meeting NFPA 13 standards for installation*. |
* NFPA 30 Flammable and Combustible Liquids Code, 2003 Edition. Section 6-6.3.1, 6.3.2, 6.3.4 |
|
|
|